JS COMBUSTION EQUIPMENTS

Pune, India gst GST No.27DREPM0650L1ZM

  • End Of Line Flame Arrestor

End Of Line Flame Arrestor

9000 INR/Piece

Minimum Order Quantity : 1 Pieces

Delivery Time : 2 Week

End Of Line Flame Arrestor Price & Specifications

Working Temperature -20A C to +60A C

Warranty 1 Years

Usage Industrial

Technology Quenching Mesh Technology

Shape Cylindrical

Product Type End Of Line Flame Arrestor

Pressure Atmospheric

Operating Pressure Atmospheric pressure to low pressure systems (up to 1.5 bar)

Mounting Type End-of-line, Vertical mount

Max Flow Rate Up to 25000 mA /h depending on model

Material Stainless Steel

Installation Type End-of-line, Vertical position

Fire Class Suitable for Class I flammable vapors

Features Non-return, Provides bidirectional flame protection, High corrosion resistance, Easy maintenance, Weather hood included

Diameter Available from 2 inches to 24 inches

Coverage Area Point-of-use (vent opening protection)

Control Type Passive Safety Device

Connectivity Type Flanged or Threaded

Color Silver

Coating Type Electropolished stainless steel

Capacity Dependent on vent size and model selection

Application Industrial, Process Safety, Flammable Gas/Vapor Storage Vents

Supply Ability 10 Per Month

Payment Terms Cash Advance (CA)

Main Domestic Market All India

Delivery Time 2 Week

About End Of Line Flame Arrestor Detail



Discover the rare excellence of our End Of Line Flame Arrestor, an elite safety solution renowned for its marvelous performance and splendid resistance in harsh environments. Featured with a corrugated stainless steel flame element and an integrated weather hood, this stellar device ensures high corrosion resistance and seamless moisture protection. Engineered with advanced Quenching Mesh Technology, it offers bidirectional, non-return flame protection for industrial applications. Easy element removal and flexible ANSI/DIN/JIS flanged connectivity make installation and maintenance remarkably convenient. Silver electropolished finish guarantees lasting durability, making it the preferred choice for elite industrial safety applications.

Elite Surface Protection for Critical Applications

Our End Of Line Flame Arrestor is splendidly designed for point-of-use vent opening protection, tailored for flammable gas and vapor storage vents across diverse industries. Used by manufacturers, distributors, and process safety managers, its cylindrical stainless steel body, corrosion resistance, and vertical mounting ensure steadfast operation. Additional features include a weather hood, non-return function, and easy maintenance, making it a marvelously dependable choice for industrial safety where robust process control is paramount.


Stellar Exports, Certifications & Timely Delivery

Featured as a preferred export to global markets, our End Of Line Flame Arrestor meets international certifications. Proposal amounts are tailored for each client's expenditure requirements. Packaging is customized for maximum device integrity during delivery. Clients from demanding sectors rely on our timely dispatch, with delivery schedules calibrated for project timelines. We ensure that every unit exported is backed by a one-year warranty and rigorous compliance standards, making us a recognized supplier worldwide.


FAQ's of End Of Line Flame Arrestor:


Q: How does the End Of Line Flame Arrestor enhance safety in industrial environments?

A: This elite flame arrestor provides bidirectional flame protection, using advanced quenching mesh technology to prevent flames from propagating back into gas or vapor storage vents, minimizing explosion risks in hazardous environments.

Q: What are the main benefits of the corrugated stainless steel flame element?

A: The rare, corrugated stainless steel element offers stellar corrosion resistance, high durability in harsh settings, and ensures reliable performance for extended operational safety and minimal maintenance needs.

Q: When is it necessary to clean or maintain the flame element?

A: Easy element removal allows periodic cleaning, typically as part of your facility's regular safety inspections or whenever there is a visible build-up of debris to maintain optimal stellar protection.

Q: Where can the End Of Line Flame Arrestor be installed?

A: Designed for vertical, end-of-line mounting, it fits directly onto vent outlets of flammable gas and vapor storage tanks, compatible with ANSI, DIN, or JIS flanged connections across industrial sites.

Q: What is the process for selecting the correct model for my needs?

A: Capacity requirements, vent diameter (2"-24"), operating pressure, and flow rate must be assessed. Our proposal includes a tailored selection matching your specific industrial application, ensuring a marvelous fit for your safety standards.

Q: How does the weather hood feature contribute to the device's performance?

A: The included weather hood provides splendid moisture and debris protection, allowing the flame arrestor to maintain optimal function and longevity even in demanding outdoor or harsh weather conditions.